Yamaha SRCP manual 15@P point number, 16@P+, 17@P

Models: SRCP

1 246
Download 246 pages 58.82 Kb
Page 189
Image 189

 

 

 

11-5 Communication Command Description

 

 

 

 

(15)@P <point number>

 

 

 

Sets the point variable P.

 

 

 

Point number

: This can be any value from 0 to 999.

Transmission example

: @P 100 c/r l/f

............................... Set the point variable P to 100.

Response example

: OK c/r l/f

 

c CAUTION

The contents of the point variable P are held even when the SRCP is turned off. However, when the program is reset or when the program reset is applied for example by switching the execution program, the point variable P will be initialized to 0.

(16)@P+

Adds 1 to the point variable P.

 

Transmission example

: @P+ c/r l/f

Increments the point variable P.

 

 

(P P+1)

Response example

: OK c/r l/f

 

(17)@P-

Subtracts 1 from the point variable P.

Transmission example

: @P- c/r l/f

Decrements the point variable P.

 

 

(P P-1)

Response example

: OK c/r l/f

 