10-5 System utilities

10-5 System utilities

10-5-1 Viewing hidden parameters

Parameters hidden in the normal state can be viewed.

Use extra caution to avoid accidentally changing the parameters when these hidden parameters are displayed.

1) On the initial screen, press F3 (SYS).

2)Press F4 (next) to change the menu display and then press F3 (UTL).

3) Press F1 (HDPR) here.

4)A confirmation message appears.

To permit display of the hidden parameters, press F1 (yes)

To hide the hidden parameters, press F2 (no).

5)The screen returns to step 3.

Display of hidden parameters is permitted un- til you press F1 (HDPR) and then F2 (no), or the SRCP controller is turned off, or until the TPB is disconnected.

[MENU] select menu

1EDIT2OPRT3SYS 4MON

[SYS] select menu

1SAFE2OPT 3UTL 4next

[SYS-UTL] select menu

1HDPR2REC

[SYS-UTL-HDPR] hidden parameter displayed ?

1yes 2no

[SYS-UTL] select menu

10

OTHER OPERATIONS

1HDPR2REC

n NOTE

The hidden parameter display is also permitted by turning on the power to the controller while holding down the ESC key on the TPB, or by connecting the TPB to the controller while holding down the ESC key.