13-3 Troubleshooting for Specific Symptom

13-3-3 Other

No.

Symptom

Possible Cause

Items to Check

Action

 

 

 

 

 

 

1

An error

1)

A dedicated I/O

• Check the signal input (by using a PLC

• Always turn off dedicated command

 

occurs when

 

command input is

monitor, etc.).

input signals when connecting the TPB

 

the TPB is

 

on.

 

to the controller.

 

connected. The

 

 

 

 

 

2)

The TPB cable is

• Check the cable wiring.

• Replace the TPB if defective.

 

TPB cannot be

 

broken.

• Try connecting another TPB if

 

 

used.

 

 

 

 

 

available.

 

 

 

 

 

 

 

 

 

 

 

 

2

Programs can

1)

DPB is used as the

 

• Use TPB (Ver. 12.50 or later).

 

be input only

 

TPB.

 

 

 

up to NO. 31,

 

 

 

 

 

2)

TPB version is

• Check that the TPB version is 12.50 or

• Replace the ROM to upgrade the

 

or point data

 

 

old.

later.

version.

 

can be

 

 

 

 

 

 

 

specified only

3)

Communication

• Check whether the wrong cable

• Use the specified communication cable.

 

up to P254, or

 

 

cable

 

 

(POPCOM cable, etc.) is being used.

(POPCOM cable is different from the

 

DIO monitor

 

 

 

specifications are

 

 

 

communication cable.) As an

 

display format

 

 

 

 

wrong.

 

 

 

 

alternative, transmit

 

is incorrect.

 

 

 

 

 

 

 

 

 

 

"@DPBVER 250" in advance.

 

 

 

 

 

 

 

 

 

 

 

 

 

4)

POPCOM/WIN

• Check that POPCOM/WIN version is

• Upgrade the POPCOM/WIN version.

 

 

 

version is obsolete.

1.10.0 or later.

 

 

 

 

 

 

 

 

 

5)

POPCOM/DOS

 

• Use POPCOM/WIN.

 

 

 

is used.

 

 

 

 

 

 

 

 

13

TROUBLESHOOTING

13-10

Page 228