8-4 Robot Language Description

8-4-3 MOVF

 

 

Function:

Moves until a specified DI number input is received.

Format:

MOVF

<point number> <DI number> <DI status>

Example:

MOVF

1, 2, 1

 

The robot moves toward P1 and stops when DI2 turns on. Program ex-

 

ecution then proceeds to the next step.

Explanation:

This is used when searching for a target position using sensors or other

 

devices.

 

The robot starts moving when all axes enter the positioning-completed

 

pulse range, and stops when the DI conditions are met. Even if the DI

 

conditions are not met, this command terminates when the robot reaches

 

the specified point and proceeds to the next step.

 

(1) Point number

 

The point number is a number designated to each point from 0 to

 

999, a total of 1000 points, and used to create point date in PNT

 

(point) mode. When a character "P" is entered here for special use, a

 

point variable defined by the "P" statement is set as the point number.

 

(See "8-4-12 P".)

 

(2) DI number

 

Specify one of the eight (0 to 7) general-purpose inputs.

 

(3) DI status

 

"1" means "on" and "0" means "off".

Other:

• The robot speed during execution of the MOVF movement can be

 

specified by PRM9. (Refer to "PRM9: MOVF speed") Note that this

 

will not be affected by the OPRT mode execution speed.

8-4-4 JMP

 

 

Function:

Jumps to a specified step in a specified program.

Format:

JMP

<label number>, <program number>

Example:

JMP 10, 8

 

Jumps to label 10 in program 8.

Explanation:

This command is used to control the flow of program execution.

 

(1) Label number

 

The label number is a number defined by the "L" statement, and

 

indicates the destination to jump. Any number from 0 to 255 can be

 

specified. (See "8-4-7 L".)

 

(2) Program number

 

The program number is a number used to identify the 100 individual

 

programs from 0 to 99.

Other:

• Even when the program number is changed by the JMP statement,

 

resetting it will return to the original program number when program

 

execution begins.

8

ROBOT LANGUAGE

8-7