Section 520 - TSAPI

Chapter 5. Maintenance and Troubleshooting

 

 

 

TDILOGERROR(dname, CAUTION, ALMLOC, alarmcnt++, "Received unknown CSTA event (0x%0x) from DBS.", etp->sublow).

The DBS has sent Panadrvr a CSTA Event that Panadrvr does not understand. This should be reported to Panasonic Technical Support.

TDILOGERROR(dname, CAUTION, ALMLOC, alarmcnt++, "Received unknown conf event (0x%0x) from DBS.", bp->code).

The DBS has sent Panadrvr a Confirmation Event that Panadrvr does not understand. This should be reported to Panasonic Technical Support.

TDILOGERROR(dname, CAUTION, ALMLOC, alarmcnt++, "DBS didn't respond to port query request.\n").

The driver has requested extension/port information from the DBS and the DBS has not responded.

“ERROR” Messages:

TDILOGERROR(dname, ERROR, ALMLOC, alarmcnt++, “Unable to select DBS”).

This alarm indicates that the DBS is not responding to communication requests from Panadrvr.

TDILOGERROR(dname, ERROR, ALMLOC, alarmcnt++, “DBS did not respond to transmitted packet”).

This alarm indicates that the DBS is not responding to communication requests from Panadrvr.

TDILOGERROR(dname, ERROR, ALMLOC, alarmcnt++, "DBS packet send fail.").

This alarm indicates that the DBS is not responding to communication requests from Panadrvr.

TDILOGERROR(dname, ERROR, ALMLOC, alarmcnt++, "DBS DCD signal down.").

Panadrvr has detected the loss of carrier detect on the API serial link. Panadrvr has just been loaded.

TDILOGERROR(dname, ERROR, ALMLOC, alarmcnt++, "DBS DCD signal down (closing all open streams).").

The same problem as above; however Panadrvr has been running. Any active client connections will be terminated.

TDILOGERROR(dname, ERROR, ALMLOC, alarmcnt++, "DBS deadman timer fail (closing all open streams).").

The DBS has failed twice in responding to keep alive packets from Panadrvr.

DBS-92-520

Issued April 2000

21

Page 27
Image 27
Panasonic Section 520 manual Error Messages