Installation the ceiling unit.

1 Attach the ceiling unit (upper section)

1)Before installing the upper section, pull the wiring through the pipe. Use an earthed mains extension lead (not supplied).

2)Make holes in the ceiling using a method appropriate for the ceiling structure and for inserting M12mm bolts. Install the upper section using a hex socket bolt (M12 not supplied), flat washer and spring washer.

Signal cable (example)

Flat washer (not supplied)

Spring washer (not supplied)

M12 bolt

(not supplied)

Earthed mains extension lead (example)

Reinforce the ceiling if it is not strong enough.

Use bolts appropriate for the ceiling material (not supplied).

Refer to the installing examples for wooden structure and concrete structure.

Installing to a wooden structure(example)

Installing to a concrete structure(example)

Mounting plate

 

 

Nut

 

 

Flat washer

 

 

(min.thickness 40mm [19/ " ] )

 

 

 

 

 

 

Nail

 

 

 

 

 

 

16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Beam

Flat washer

Spring washer

Ceiling board

 

M12 bolt

 

 

 

 

 

 

 

Concrete

Anchor nut or curled plug(M12)

Flat washer Spring washer M12 bolt