SETTING PROCEDURES
The following setting procedures are described on the
assumption that this model is used in combination with
WJ-SX550C Matrix Switcher and WV-CU550C/CJ
System Controller. In case a controller other than WV-
CU550C is used, refer to the table on page 12.

Menu Display

Setup Menu Display

WV-CU550C/CJ
1. Select the number of the camera you want to set up
and a monitor to display SET UP MENU.
2. Display the D4 menu on the LCD by pressing the
appropriate direction buttons.
3. Press the F1 button.
SET UP MENU appears on the monitor.
4. To close SET UP MENU, press the F4 button.
WV-CU360C/CJ
Press the CAM SETUP key for 2 seconds or more to
open the SETUP menu.
WV-CU161C
Press the CAMERA SETUP key for 2 seconds or
more to open the SETUP menu.
WV-RM70
1. Turn the MODE SELECTION switch to the NORMAL
or ALARM OFF position.
2. Press the PROG switch for 2 seconds or more to
open the Program menu.
3. Move the cursor to Camera Set Up Menu, and press
the SET switch to open SETUP MENU.

Submenu Display

The items marked O can be selected/changed on the
submenu.
Move the cursor to an item with the O mark and
press the CAM (SET) key. The submenu appears.
-17-
F1
F1 F2 F3 F4
Camera Set Up Menu
Res A.Res Exit
F2 F3 F4
Camera Set Up Menu
On Exit
** SET UP MENU **
PRESET 1
MAP
HOME POSITION
SELF RETURN
AUTO MODE
AUTO PAN KEY
DIGITAL FLIP
SPECIAL1
CAMERA
RS485 SET UP
PASSWORD LOCK OFF
OFF
OFF
OFF
AUTO PAN
ON
** RS485 SET UP **
UNIT NUMBER
SUB ADDRESS
BAUD RATE
DATA BIT
PARITY CHECK
STOP BIT
XON/XOFF
WAIT TIME
ALARM DATA
DELAY TIME
RET
1
1
19200
8
NONE
1
NOT USE
OFF
AUTO2
OFF