CONNECTIONS
How to Assemble the Cable with the Accessory
Connector
Strip back the cable jacket approx. 3 mm (0.1 inch)
and separate the individual conductors.
Prepare the individual conductors for clamping. Use
MOLEX band tool part number 57027-5000 (for UL-
Style Cable UL1015) or 57026-5000 (for UL-Style
UL1007) for clamping the contacts.
After clamping the contacts, push them into the proper
holes in the accessory connector of this camera until
they snap in place.
CAUTIONS
Shrinking the cable-entry seal is a one-time
procedure. Do not shrink the cable-entry seal until
ascertaining that the unit is functioning.
CONNECT THIS TO 24 V AC CLASS 2 POWER
SUPPLY ONLY.
-50-
Precautions
The following connections should be made by qualified service personnel or system installers in accordance
with all local codes.
See the reverse side of the cover page for main lead connection.
The coaxial cable length (RG-59/U, BELDEN 9259) for the connection
is up to 1 200 meters (4 000 ft.)
To VIDEO IN
(CAMERA IN)
Video output
24 V AC
BNC plug
Coaxial cable
RS485 cable
Data port
BNC plug
Alarm in
Alarm out
To sensors
To indicators
24 V AC cable
Note: When powered up, the unit performs a self-check (including one panning, tilting, zooming and focusing
operation).

Recommended wire gauge sizes for 24 V AC line

#24
(0.22mm2)
Copper wire size
(AWG)
Length
of cable
(approx.)
(m)
(ft)
#22
(0.33mm2)
#20
(0.52mm2)
#18
(0.83mm2)
20 30 45 75
65 100 160 260
Pin no. Power source
1
2
3
4
24 V AC LIVE
24 V AC NEUTRAL
Ground
Not use

1

3

2

4

24 V AC Power Supply Connection
Accessory Connector Information
Contact Insert
Up A
Approx.
3 mm (0.1 inch)
Insert the wire until A position
and clamp the contacts.
Wire
Up
Contact
Wire
Approx.
3 mm (0.1 inch)
Insert the wire until A position
and clamp the contacts.
Contact
Up Wire
Up Wire
Contact