CONNECTIONS
Precautions
•The following connections should be made by qualified service personnel or system installers in accordance with all local codes.
•See the reverse side of the cover page for main lead connection.
24 V AC |
|
| 24 V AC cable |
|
Data port |
|
| RS485 cable |
|
|
|
| Coaxial cable | To VIDEO IN |
|
| BNC plug | BNC plug | (CAMERA IN) |
Video output | Alarm in |
| ||
|
|
|
To sensors
To indicators
Alarm out
✻The coaxial cable length
Note: When powered up, the unit performs a
•24 V AC Power Supply Connection Recommended wire gauge sizes for 24 V AC line
Copper wire size | #24 | #22 | #20 | #18 | ||
(AWG) |
| (0.22mm2) | (0.33mm2) | (0.52mm2) | (0.83mm2) | |
|
|
|
|
|
| |
Length | (m) | 20 | 30 | 45 | 75 | |
of cable |
|
|
|
|
| |
(ft) | 65 | 100 | 160 | 260 | ||
(approx.) | ||||||
|
|
|
|
|
|
Accessory Connector Information
Pin no. | Power source |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1 | 24 V AC LIVE |
|
|
|
|
|
|
|
|
|
2 | 24 V AC NEUTRAL |
| 4 |
|
| 3 | ||||
3 | Ground |
|
|
|
|
|
|
|
|
|
2 |
| 1 | ||||||||
4 | Not use |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
How to Assemble the Cable with the Accessory Connector
Strip back the cable jacket approx. 3 mm (0.1 inch) and separate the individual conductors.
. |
|
Approx. |
|
3 mm (0.1 inch) | Wire |
3 mm (0.1 inch) |
Up A
Contact | Insert |
InsertthethewirewireuntiluntilA Apositionposition
and clamp the contacts. and clamp the contacts.
Prepare the individual conductors for clamping. Use MOLEX band tool part number
After clamping the contacts, push them into the proper holes in the accessory connector of this camera until they snap in place.
Up
WireWire
Contact
CAUTIONS
•Shrinking the