RS485 Setting

The 4-bit DIP switch is used for RS485 termination.

4-bit DIP SW

 

 

 

 

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

2

 

3

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BP 1

 

 

Function

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Switch

 

ON

 

Termination ON

 

 

 

position

 

OFF

 

Termination OFF *

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BP 2

BP 3

BP 4

 

Function

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Switch

ON

ON

ON

Half duplex (2 line)

 

position

OFF

OFF

OFF

Full duplex (4 line) *

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Notes:

Defaults are marked with *.

BP stands for Bit Position.

Full duplex is not available in a daisy chain connection. (Panasonic system controllers only)

3.Assemble the Camera

Reverse the disassembly procedure. Take care not to cut any cables.

Precaution: Be sure to select a ceiling board strong enough to support 4 times the total weight of the camera.

a.Sideway Cable Exit

Prepare a cutout in the diecast case and decoration cover as shown in the following figures.

Cutout in Diecast Case

Cutout in Decoration Cover

Note: Remove sharp edges to protect the cables.

b.Top Cable Exit

Prepare a hole in the ceiling board to run the cables.

1.Mark the mounting holes on the ceiling, using the removed camera mounting base as a template.

Marking

2.Fix the camera mounting base to the ceiling with four screws (not provided, M4).