■Connections
Cautions:
•This product should be installed and connected in conformity with NEC by qualified service personnel or system installers.
•Do not use a transformer with a capacity of more than 20 V A.
•Use a class 2 power supply.
•To prevent fire or electric shock hazard, use a UL listed cable
•Be sure to connect the GND (grounding) lead of the camera and grounding terminal of the power supply.
Network
|
| To network |
| Adapter | |
| (supplied) | |
Video output | BNC | BNC |
|
| |
|
| To Video IN (CAMERA IN) |
|
| To peripherals |
| Control cable | Adapter (supplied) |
|
| Brown (Live) |
Power 24 V AC |
| Blue (Neutral) |
|
| |
|
| Green/Yellow (GND) |
|
| Black (Live) |
|
| For optional heater |
|
| White (Neutral) |
●Power Connection
Use individual power sources for the camera and optional heater unit.
• Wire colors & functions |
| ||
Wire color |
| Function | Note |
|
|
|
|
Brown | 24 | V AC Live | For camera |
|
|
| 8.6 W |
Blue | 24 | V AC Neutral | |
|
|
| |
Green/Yellow | GND |
| |
|
|
|
|
Black | 24 | V AC Live | For optional heater |
|
|
| 12.1 W |
White | 24 | V AC Neutral | |
|
|
|
|
•Cable length and wire gauge
The recommended cable length and thickness are shown in the table for reference. The voltage sup- plied to the power terminals of the camera should be between 19.5 V AC and 28 V AC.
Copper wire size | #24 | #22 | #20 | #18 | ||
(AWG) |
| (0.22mm2) | (0.33mm2) | (0.52mm2) | (0.83mm2) | |
|
|
|
|
|
| |
Length | (m) | 20 | 30 | 45 | 75 | |
of cable |
|
|
|
|
| |
(ft) | 65 | 100 | 160 | 260 | ||
(approx.) | ||||||
|
|
|
|
|
|