Pantech WV-NW474S manual Customizing Alarm Notice E-Mail, Table of Substitution letters, Step

Models: WV-NW474S

1 58
Download 58 pages 53.63 Kb
Page 53
Image 53

Customizing Alarm Notice E-Mail

You can customize the contents of e-mails notifying the recipient of alarm events and their dates. Take the following steps:

Step 1

Create an alarm e-mail as shown below using any text editor, and save it as "almmail.tmpl" in text file format on your PC.

Example of text file (almmail.tmpl) Alarm arisen at %h%i

Date : %y. %m. %d %t

Number of alarm images: %n

URL of Alarm Image: %u Display example

Alarm arisen at NW474 192.168. 0.10 Date: 2003.02.04 13:55:40 Number of alarm image: 5

URL of Alarm Image: http://192.168.0.10/ ALM0000_00.jpg

Table of Substitution letters

Item

Substitution Letter

Description (indication type etc.)

Alarm date (year)

%Y

4-digit-indication 2000 to 2099

Alarm date (year)

%y

2-digit-indication

00 to 99

Alarm date (month)

%m

2-digit-indication

01 to 12

Alarm date (month)

%M

3-letter-indication

Jan to Dec

Alarm date (day)

%d

2-digit-indication

01 to 31

Alarm date (time)

%t

hour:minute:second 24-hour indication

Sender E-mail Address

%s

 

 

Host address of camera

%i

192.168.0.1 type indication

Origin of alarm

%p

Terminal, VMD

 

File name of alarm image

%f

ALM0000_00.JPG type indication

URL of alarm image

%u

http://192.168.0.1/ALM0000_00.JPG

(IP address)

 

Blank appears in case of no file.

Number of alarm image

%n

0 to 40

 

File Name: almmail.tmpl, a template for alarm e-mail notifications.

Use the provided file name.

Step 2

Start up the Windows DOS prompt and connect by inputting the IP address of the unit.

For the FTP software, use the user name and administrator password (level 1) registered in the User Setting win- dow.

If no administrator has been registered, proceed as follows:

User Name: admin

Password: None

Step 3

Upload the file(almmail.tmpl) to this unit.

Notes:

Do not upload with FTP when connecting with low baud rate lines such as ISDN.

To display "%" enter the symbol twice as "%%".