MIB Definition

SYNTAX INTEGER { self-test(1), local-loop(2), rem-digital-loop(3), loc-digital-loop(4), dte-loop(5), bert(6), local-loop-bert(7), rdl-bert(8), digital-test(9), end-to-end-test(10), abort(11)

}

ACCESS read-write STATUS mandatory

DESCRIPTION

ºThis object is the test type. Test type self-test(1) performs an internal self-test of the device. Test type local-loop(2) places the device into local loopback (for modems, this is a CCITT V.54 Loop 3). Test type rem-digital-loop(3) places the device in a remote digital loopback (for modems, this is a CCITT V.54 Loop 2). Test type loc-digital-loop(4) forces a local device to loopback any data received from the remote device (this is useful if the remote device is incapable of initiating a remote digital loopback from its location). Test type dte-loop(5) loops a DSU's data port back to the DTE/DCE interface on a per-port basis without affecting the operation of the remaining ports. Test type bert(6) initiates a pattern

test. Test type local-loop-bert(7) places the device into local loopback and initiates a pattern test. Test type rdl-bert(8) places the device into remote digital loopback and initiates a pattern test. Test type digital-test(9) initiates a digital test of a pair of DSUs or DBMs and the data circuit between them. Test type end-to-end-test(10) initiates an end to end test of two devices. Test type abort aborts the current test.º

::= { nmsTestEntry 3 }

±±

±±Test Duration

nmsTestDuration OBJECT-TYPE