Device Enterprise MIB Definition
±±External Leads Group (dev 6)
±±Textual Convention for External Lead objects
ExternalLead ::=
INTEGER { lead-off(1), lead-on(2)
}
devExtLeadsOutPin12 OBJECT-TYPE SYNTAX ExternalLead ACCESS read-write
STATUS mandatory
DESCRIPTION
ºRS-232 output pin 12 (port 1).º ::= { devExtLeads 1 }
devExtLeadsOutPin13 OBJECT-TYPE SYNTAX ExternalLead ACCESS read-write
STATUS mandatory
DESCRIPTION
ºRS-232 output pin 13 (port 1).º ::= { devExtLeads 2 }
devExtLeadsInPin19 OBJECT-TYPE SYNTAX ExternalLead ACCESS read-only
STATUS mandatory
DESCRIPTION
ºRS-232 input pin 19 (port 1).º ::= { devExtLeads 3 }
devExtLeadsInPin23 OBJECT-TYPE SYNTAX ExternalLead ACCESS read-only
STATUS mandatory
DESCRIPTION
ºRS-232 input pin 23 (port 1).º ::= { devExtLeads 4 }
Issue 2 December 1996 B-33