Paradyne 3700-A2-GB20-10 manual Issue 2 December 1996 B-35

Models: 3700-A2-GB20-10

1 120
Download 120 pages 23.78 Kb
Page 92
Image 92

Device Enterprise MIB Definition

ºSetting this attribute to busy(1) will cause the device to busy out the attached analog phone line. Setting this attribute to clear(2) will cause the device to unbusy the analog phone line. This object will always return a value of unknown(3). To test the current busy state, refer to the devStatusAlert object.º

::= { devCommand 3 }

±± Switch To Dial-Backup/Dial-Standby/Service-Line

devCommandSwitchTo OBJECT-TYPE SYNTAX INTEGER {

dial-backup(1), dial-standby(2), leased(3),

service-line(4), ±± switch for mgmt mode unknown(5)

}

ACCESS read-write STATUS mandatory

DESCRIPTION

ºSwitch service mode to dial-backup(1), dial-standby(2), leased (3), or service-line(4). This object always returns a value of unknown(5).º

::= { devCommand 4 }

±± Enable/Disable Device

devCommandEnable OBJECT-TYPE SYNTAX INTEGER {

enable-device(1), disable-device(2), unknown(3)

}

ACCESS read-write STATUS mandatory

DESCRIPTION

ºWrite to enable(1) or disable(2) the device.

This object always returns a value of unknown(3).º ::= { devCommand 5 }

±± Reset Device

Issue 2 December 1996 B-35

Page 92
Image 92