MIB Definition

nmsTestLocalTotalSeconds OBJECT-TYPE SYNTAX INTEGER

ACCESS read-only STATUS mandatory

DESCRIPTION

ºTotal seconds for local device. (For 3600 model type devices, this variable is also called elapsed seconds.)º

::= { nmsTestEntry 9 }

±± Local Error Seconds

nmsTestLocalErrorSecondsValidity OBJECT-TYPE SYNTAX TestResultValidity

ACCESS read-only STATUS mandatory

DESCRIPTION

ºValidity of the nmsTestLocalErrorSeconds test result object.º ::= { nmsTestEntry 10 }

nmsTestLocalErrorSeconds OBJECT-TYPE SYNTAX INTEGER

ACCESS read-only STATUS mandatory

DESCRIPTION

ºErrored seconds elapsed for local device. (The value is not used for 3600 model type devices.)º

::= { nmsTestEntry 11 }

±± Local Total Blocks (Bits for 3600 DSU)

nmsTestLocalTotalBlocksValidity OBJECT-TYPE SYNTAX TestResultValidity

ACCESS read-only STATUS mandatory

DESCRIPTION

ºValidity of the nmsTestLocalTotalBlocks test result object.º ::= { nmsTestEntry 12 }

nmsTestLocalTotalBlocks OBJECT-TYPE SYNTAX INTEGER

ACCESS read-only STATUS mandatory

DESCRIPTION

ºTotal blocks for local device.º ::= { nmsTestEntry 13 }

A-20Issue 2 December 1996

Page 53
Image 53
Paradyne 3700-A2-GB20-10 manual 20Issue 2 December