MIB Definition

SYNTAX INTEGER ACCESS read-write STATUS mandatory

DESCRIPTION

ºTest duration in seconds (or blocks). Only applicable for the following test types: bert, local-loop-bert, rdl-bert, digital-test, end-to-end-test.º

::= { nmsTestEntry 4 }

±±

±±Port Number

nmsTestPortNumber OBJECT-TYPE SYNTAX INTEGER {

aggregate(1),

port1(2),

port2(3),

port3(4),

port4(5),

port5(6),

port6(7)

}

ACCESS read-write STATUS mandatory

DESCRIPTION

ºPort number. Only applicable for multi-port devices. Also only applicable for the following test types: rem-digital-loop, loc-digital-loop, dte-loop, bert, local-loop-bert, rdl-bert, digital-test, end-to-end-test.º

::= { nmsTestEntry 5 }

±±

±±Remote Device Name

nmsTestRemoteName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..15)) ACCESS read-write

STATUS mandatory

DESCRIPTION

ºRemote device name. Only applicable for the following test types: digital-test, end-to-end-test.º