Paradyne 3700-A2-GB20-10 manual Issue 2 December 1996 B-11

Models: 3700-A2-GB20-10

1 120
Download 120 pages 23.78 Kb
Page 68
Image 68

Device Enterprise MIB Definition

±± Device Status Group (dev 3)

devStatusConnectedDevice OBJECT-TYPE SYNTAX DisplayString (SIZE (0..15)) ACCESS read-only

STATUS mandatory

DESCRIPTION

ºThe device name of the connected device. A zero length string will be returned if the information is unavailable.º

::= { devStatus 1 }

devStatusConnectTime OBJECT-TYPE SYNTAX TimeTicks

ACCESS read-only STATUS mandatory

DESCRIPTION

ºConnect time (in seconds).º ::= { devStatus 2 }

devStatusAlert OBJECT-TYPE SYNTAX UInteger32 ACCESS read-only STATUS mandatory

DESCRIPTION

ºThe current alerts for the device. The bit position number starting with 0 and counting from the right (low order) bit will indicate each active Primary Alert. The Primary Alerts and their bit positions are defined as follows:

device-fail(0), config-change-notify(1), test-mode(2), disabled(3), out-of-threshold(4), facility-alarm(5), external-alarm(6), streaming-terminal(7), access-security(8), dial-backup-active(9), dte-alarm(10), subnormal-speed(11), primary-channel-interrupt(12), firmware-downloading(13), make-busy-mode(14),

Issue 2 December 1996 B-11

Page 68
Image 68