About HotWire Model 7924 Termination Units

Typical Configurations

HotWire Model 7924 standalone units can be used in campus applications where long loop distances normally require the campus to contract with the local telephone exchange carrier to deliver private line services across the campus.

Figure 1-1shows two typical campus applications where remote PBXs or multiplexers are interconnected across a campus using two HotWire Model 7924 standalone units. In each pair, one unit is configured as a central site or central office (CO) unit and the other is the remote or customer premises (CP) unit.

The HotWire Model 7924 standalone unit is configured at the factory to operate at the CP side of a T1 HDSL connection. (Conversely, HotWire Model 7924 nest cards are configured for CO operation.) The central site unit must be reconfigured for CO operation in these configurations.

PBX

Cross-campus

 

2- or 4-wire

 

DSX-1

facility

DSX-1

DSX-1 Unit

 

DSX-1 Unit

Customer Premises

 

Central Site

PBX

97-15295

Multiplexer

Cross-campus

Multiplexer

2- or 4-wire

DSX-1

facility

DSX-1

DSX-1 Unit

 

DSX-1 Unit

Customer Premises

 

Central Site

 

 

97-15296

Figure 1-1. Campus Network Applications

7924-A2-GB20-30

October 1997

1-3

Page 12
Image 12
Paradyne 7924 manual Typical Configurations, Campus Network Applications