Customizing V.35-Compatible Units

Possible values for each parameter are listed in Table 5-1. See Appendix A, Worksheets, for help in selecting the appropriate configuration options for your application.

Table 5-1. V.35-Compatible Units Configuration Options

1) HDSL Card Type

Possible Settings: CP, CO

Default Setting: CP

Indicates the placement of the unit in the network configuration. To toggle the card type, enter 1 at the Config prompt.

CP ± Unit is on the customer premises side of the HDSL connection.

CO ± Unit is on the central office (or central site) side of the HDSL connection.

2) Loops Enabled

Possible Settings: Single, Dual

Default Setting: Dual

Specifies which loops on the HDSL line are to be used in the connection. To change the loops that are enabled, enter 2 at the Config prompt. The system then prompts you to specify either (S)ingle or (D)ual Loops.

Dual ± Loops A and B are enabled.

Single ± Only Loop A is enabled.

3) Payload Rate

Possible Settings: 1 through 9 (for 64 through 1536 kbps)

Default Setting: 9 (1536 kbps)

Specifies the desired payload rate.

1

± 1 x 64 (64 kbps)

6

± 8 x 64 (512 kbps)

2

± 2 x 64 (128 kbps)

7

± 12 x 64

(768 kbps)

3

± 3 x 64 (192 kbps)

8

± 16 x 64

(1024 kbps)

4

± 4 x 64 (256 kbps)

9

± 24 x 64

(1536 kbps)

5

± 6 x 64 (384 kbps)

N ± No change to rate

Options 8 and 9 (1024 and 1536 kbps) are only available when Loops A and B are enabled. If only Loop A is enabled, the maximum payload rate is 768 kbps (option 7).

You must reset the board for changes to the card type or loops enabled

(options 1 or 2) parameters to take effect. A system message is displayed on the terminal to remind you to reset the board. To reset the board, choose option 4 from the Main Menu or cycle the power on the board.

All configuration settings are stored in nonvolatile memory and are not affected by the reset.

The transmit timing, HDSL interface/rate, firmware revision numbers, and serial number displayed on the Board Configuration screen cannot be changed.

7924-A2-GB20-30

October 1997

5-3

Page 27
Image 27
Paradyne 7924 manual V.35-Compatible Units Configuration Options, ± 6 x 64 384 kbps ± No change to rate