Monitoring the Unit

The type of statistics displayed under the T1 Errors column depends on the type of framing selected. When the unit is configured for D4 framing, FAS (Frame Alignment Signal) errors are reported. When the unit is configured for ESF framing, CRC (Cyclic Redundancy Check) errors are reported.

Refer to the Glossary for definitions of the errors reported.

Remote Unit Information

The same type of information provided for the locally attached unit can also be displayed (but not changed) for the unit on the other side of the connection.

You can display information about the CO unit by using the HTUC menu options from a terminal attached to the CP unit, and you can display information about the CP unit by using the HTUR menu options from a terminal attached to the CO unit.

To access the HTUC or HTUR menu, enter 7 at the Main Menu Command prompt.

***** HTUC Menu *****

1)Board Status

2)Performance Monitor

3)Board Configuration

4)Line Build Out Configuration Help ?) Redisplays this Menu