Customizing DSX-1-Compatible Units

Table 4-1. DSX-1-Compatible Units Configuration Options (2 of 2)

5) Line Build Out

Possible Settings: 0 to 133 ft, 133 to 266 ft, 266 to 399 ft, 399 to 533 ft, 533 to 655 ft

Default Setting: 0 to 133 ft

To change the line build-out length, enter 5 at the Config command prompt. You will then be prompted to select from the following options:

1)0 to 133 ft

2)133 to 266 ft

3)266 to 399 ft

4)399 to 533 ft

5)533 to 655 ft N) No change

NOTE: Additional options may be displayed on your terminal. These other options (for ±7.5, ±15, and ±22.5 dB) are not for use with this product. Use of these options will cause a weak signal and degrade performance. Select from options 1 through 5 only.

You must reset the board for changes to the card type or loops enabled (options 1 or 2) to take effect. A system message is displayed on the terminal to remind you to reset the board. To reset the board, choose option 4 from the Main Menu or cycle the power to the board.

All configuration settings are stored in nonvolatile memory and are not affected by the reset.

The HDSL rate type, firmware revision numbers, and the serial number displayed on the Board Configuration screen cannot be changed.

4-4

October 1997

7924-A2-GB20-30

Page 22