Paradyne 7924 Board Status for DSX-1-Compatible Unit, Board Status for V.35-Compatible Unit

Models: 7924

1 58
Download 58 pages 15.77 Kb
Page 31
Image 31

Monitoring the Unit

Board Status

Board Status option from the Main Menu displays HDSL circuit operational status.

Enter 1 at the Main Menu Command prompt to display board status.

Command1

 

T1 STATUS:

Network is UP

LOOPBACK STATUS: OFF

HDSL STATUS:

LOOP A is UP, LOOP B is UP

S/N RATIO:

Loop A = 44.0 dB, Loop B = 43.5 dB

Command

 

 

Board Status for DSX-1-Compatible Unit

 

 

Command1

 

DTR:

ACTIVE

DSR:

ACTIVE

LOOPBACK STATUS: OFF

HDSL STATUS:

LOOP A is UP, LOOP B is UP

S/N RATIO:

Loop A = 44.0 dB, Loop B = 43.5 dB.

Command

 

 

 

Board Status for V.35-Compatible Unit

HT1 STATUS displays one of the following:

ÐNetwork is Up

ÐReceive Carrier Loss

ÐReceive Remote Alarm

ÐReceive Unframed All 1's.

HDTR and DSR are either ACTIVE or INACTIVE. DSR becomes active in response to DTR (with HDSL loops up and data transmission possible).

HLOOPBACK STATUS is either ON or OFF.

HHDSL STATUS displays whether each loop is UP, DOWN, or DISABLED.

HS/N (Signal-to-Noise) RATIO is not displayed if loops are down or disabled.

6-2

October 1997

7924-A2-GB20-30

Page 31
Image 31
Paradyne 7924 manual Board Status for DSX-1-Compatible Unit, Board Status for V.35-Compatible Unit