Image 26

Customizing V.35-Compatible Units

Making Changes from the Terminal Interface

The Board Configuration menu displays the current board software and hardware settings. It also allows you to change certain parameters on the board.

This function is affected by the status of the switchpack (DIP switch control) setting.

HWhen operating in Terminal Mode (the system default) you can make configuration changes through the terminal menus.

HWhen operating in Switchpack Mode, you can display configuration parameters using the terminal menus, but any configuration changes must be made using the switchpacks and jumpers on the board hardware. Refer to Making Changes in Switchpack Mode on page 5-4.

To access the Board Configuration menu, enter 3 at the Main Menu Command prompt.

Command3

 

Board Configuration:

 

1)

HDSL Card Type

± CP

 

HDSL Interface/Rate

± V.35 T1

2)

Loops Enabled

± Dual Loop (Loops A and B)

3)

Payload Rate

± 1536 Kbps (24x64)

 

Transmit Timing

± Loop

 

HDSL FW Rev

± 03

 

AT+T FW Rev

± 1.17

 

CP Serial #

± 85649

±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±

1±3)

Board Configuration

 

4)

Switch pack Definitions

?)

Redisplays this menu

 

Q)

Quit

 

Config