C. Configuration Options
C-2 March 2001 3160-A2-GB24-10

The configuration tables include a description of each configuration function and

its available selections. In the tables, the top line of each configuration option

entry indicates the factory default setting.

DTE Interface Configuration Options
NOTE:

These configuration options are only available for 2-port and 4-port

DSU/CSUs.

Table C-1. DTE Interface Configuration Options (1 of 2)

DTE Port: Enab
Next Enab Disab Prev
DTE Drop/Insert (DSX-1) Port. Enables the use of the DTE Drop/Insert (DSX-1) port.
Enab Allows the use of the DTE Drop/Insert (DSX-1) interface.
Disab Prohibits the use of the DTE Drop/Insert (DSX-1) interface.
NOTE: When this configuration option is disabled, you cannot display or configure any
other DTE Interface configuration options. If the clock source configuration option is
set to DTE, it is changed to NET.
DTE Framing: ESF (Factory 1) D4 (Factory 2)
Next D4 ESF Prev
DTE Line Framing Format. Designates the framing format for the DTE Drop/Insert
(DSX-1) interface.
D4 Configures for the D4 framing format.
ESF Configures for the Extended Superframe framin g format.
DTE Coding: B8ZS (Factory 1) AMI (Factory 2)
Next AMI B8ZS Prev
DTE Line Coding Format. Designates the line coding format to be used on the DTE
Drop/Insert (DSX-1) interface.
AMI Uses the Alternate Mark Inversion coding for mat.
B8ZS Uses the Bipolar 8 Zero Suppression coding format.
Equal: 0133
Next 0133 133266 266399 399533 533655 Prev
DTE Line Equalization. Specifies the DTE line equalization compensation parame ters that
permit a standard DTE Drop/Insert (DSX-1) signal to be delivered over a distance of up to
655 feet.