C. Configuration Options
3160-A2-GB24-10 March 2001 C-7
Near-end: Disab
Next Disab Maint Send Both Prev
Near-End Performance Statistics. Specifies whether the DSU/CSU maintains near-end
performance statistics and sends performance report messages (PRMs) for a particular
port.
Disab Disables near-end performance statistics and does not send PRMs.
Maint Maintains near-end performance statistics for this port.
Send Sends PRMs over the ports EDL every second. Each PRM contains t h e
performance statistics for the previous 4seconds.
Both Maintains near-end performance statistics and sends PRMs over the ports EDL.
NOTES:
This configuration option is not available if EDL is disabled.
If the local DSU/CSU is configured to send near-end performance statistics, then
the remote device must be configured to maintain far-end performance statistics.
Far-end: Disab
Next Disab Maint Prev
Far-End Performance Statistics. Specifies whether to monitor for far-end performance
report messages (PRMs) and maintain far-end performance registers for a particular port.
Disab Disables far-end performance statistics.
Maint Monitors the ports EDL for PRMs and maintains far-end performance statistics.
NOTES:
This configuration option is not available if EDL is disabled.
If the local DSU/CSU is configured to maintain far-end performance statistics, then
the remote device must be configured to send near-end performance statistics.
Mgmt Link: Disab
Next Enab Disab Prev
EDL Management Link. Specifies whether the EDL management link is enabled for a
particular port. Selecting Enab allows SNMP or Telnet traffic to flow over the 4kbps
in-band data link provided by EDL.
Enab Enables the ports EDL management link.
Disab Disables the ports EDL management link.
NOTES:
This configuration option is not available if EDL is disabled or the FDL is enabled.
If the local DSU/CSUs EDL is enabled, then the remote devices EDL must also be
enabled.
Table C-2. Port Configuration Options (5 of 5)