F. SNMP MIB Objects
3160-A2-GB24-10 March 2001 F-25
Generic Interface Test Table, Generic Interface MIB
The test table provides access to additional tests (loopbacks and patter n tests)
that are not in the interface group of MIB II.
Generic Interface Test Table ifExtnsTestType Object (ifExtnsTestEntry 4)
This object is a control variable used to start and stop operator-i nitiated tests on
the interface. It provides the capability to:
Start/stop the Monitor QRSS test pattern on the network interface.
Start/stop the Send QRSS/511 test pattern on a synchron ous data port.
Start sending a V.54/FT1 UP/DOWN code to the remote unit for a
synchronous data port.
Start/stop the Monitor QRSS/511 test pattern on a synchro nous data port.
Start/stop the DCLB/DTLB loopback test on a synchronous data por t.
The following object identifiers are used to control the tests on the interface.
noTest Stops the test in progress on the interface.
testFullDuplexLoopBack Initiates a DCLB on the interface. Only supported
for the data ports.
testLoopDTLB Initiates a DTLB on the interface. Only supported for the data
ports.
testMonQRSS Initiates a Monitor QRSS test on the interface. Supported for
the data ports and the network interface.
testMon511 Initiates a Monitor 511 test on the interface. Only supported for
the data ports.
testSendQRSS Initiates a Send QRSS test on the interface. Only support ed
for the data ports.
testSend511 Initiates a send 511 test on the interface. Only supported for
the data ports.
testSendV54Up Sends a V54 up code to the remote unit. Only supported for
the data ports.
testSendV54Down Sends a V54 down code to the remote unit. Only
supported for the data ports.
testSendFT1Up ends a FT1 up code to the remote unit. Only suppor ted for
the data ports.
testSendFT1Down Sends a FT1 down code to the remote unit. Only
supported for the data ports.