C. Configuration Options
C-18 March 2001 3160-A2-GB24-10
User Interface Configuration Options
NOTE:

A circular symbol () identifies configuration options that are available on

standalone DSU/CSUs only. A triangular symbol () identifies configuration

options that are available on carrier-mounted DSU/CSUs only.

Table C-7. User Interface Configuration Options (1 of 11)

Self-Test: Enab
Next Enab Disab Prev
Initial Self-Test. Specifies whether the DSU/CSU perfor ms a device self-test at power-up
and after a device reset.
Enab Enables a self-test.
Disab Disables the self-test.
FP Access: Enab
Next Enab Disab Prev
Front Panel Access. Determines whether front panel access or display is allowed at the
DSU/CSU.
Enab Allows the front panel to access and display data.
Disab Prevents the access and display of data.
NOTE: This configuration option is available on standalone DSU/CSUs only.
FP Pass: Disab
Next Enab Disab Prev
Front Panel Pass-Through. Allows dial-out access to a remote DSU/CSU using the front
panel pass-through operation.
Enab Allows dial-out access to a remote DSU/CSU.
Disab Prevents dial-out access to a remote DSU/CSU.
NOTE: This configuration option is available on standalone DSU/CSUs only.
Dial-In: Enab
Next Enab Disab Prev
Dial-in Access. Allows dial-in access to the DSU/CSU. For stand al one DSU/C SU s, dial-in
access is through the modem port. For carrier-mounted DSU/CSUs, dial-in access is
through an external device that is connected to the communication port.
Enab Allows dial-in access to the DSU/CSU.
Disab Prevents dial-in access. Incoming calls to the DSU/CSU are not answered.
NOTE: To enable Dial-In for carrier-mounted DSU/CSUs, the external device must be
configured for automatic answer and the ComExtDev configuration option must be
enabled.