3. Configuration Options
9000-A2-GB31-00 December 2002 3-93
Configuring SNMP Traps and Trap Dial-Out
Select SNMP Traps from the Management and Communication menu to configure
SNMP traps and dial-out when a trap is generated (see Table 3-36, SNMP Traps
and Trap Dial-Out Options).
Main MenuConfigurationManag ement and Communication SNMP
Traps
See the FrameSaver SLV SNMP Reference for trap format standards and special
trap features, including RMON-specific traps, and the default settings that will
generate RMON-specific SNMP traps.
Access Type
Possible Settings: Read, Read/Write
Default Setting: Read
Specifies the type of access allowed for an authorized NMS when IP address validation is
performed.
Display Conditions – This option appears for each trap manager specified in the
Number of Trap Managers configuration option.
Read – Allows read-only access (SNMP Get command) to the MIB objects. This includes
all objects specified as either read-only or read/write in the MIB RFCs.
Read/Write – Allows read and write access (SNMP Get and Set commands) to the MIB
objects. However, access for all read-only objects is specified as read-only.
Table 3-35. SNMP NMS Security Options (2 of 2)
Table 3-36. SNMP Traps and Trap Dial-Out Options (1 of 6)
SNMP Traps
Possible Settings: Enable, Disable
Default Setting: Disable
Determines whether the FrameSaver unit s ends trap messages to the currently
configured SNMP trap manager(s).
Enable – Sends trap messages.
Disable – Does not send trap messages.
Number of Trap Managers
Possible Settings: 1 – 6
Default Setting: 1
Specifies the number of SNMP management systems that will receive SNMP trap
messages from the FrameSaver unit. An NMS IP Address must be configured in the NMS
nIP Address configuration option for each trap manager to receive trap messages.
1 – 6 – Specifies the number of trap managers (inclusive).