3. Configuration Options

Table 3-34. Telnet and FTP Session Options (1 of 2)

Telnet Session

Possible Settings: Enable, Disable

Default Setting: Enable

Specifies whether the FrameSaver unit will respond to a session request from a Telnet client on an interconnected IP network.

Enable – Allows Telnet sessions between the FrameSaver unit and Telnet client.

Disable – Does not allow Telnet sessions.

Telnet Login Required

Possible Settings: Enable, Disable

Default Setting: Disable

Specifies whether a user ID and password (referred to as the login) are required to access the menu-driven user interface via a Telnet session. If required, the login used is the same login used for an menu-driven user interface session. This option does not affect the TS Access Management Link.

Enable – Requires a login to access a Telnet session.

Disable – Does not require a login.

Session Access Level

Possible Settings: Level-1, Level-2, Level-3

Default Setting: Level-1

Specifies the highest security level allowed when accessing the menu-driven user interface via a Telnet session. If a login is required for the session, the effective access level is also determined by the user’s access level. When a login is not required, the effective access level is determined by this option. This option does not affect the TS Access Management Link.

NOTE: The effective access level is always the lowest one assigned to either the session or the user. For example, if the assigned Session Access Level is Level-2, but the User Access Level is Level-3, then only level-3 access is allowed for the session.

Level-1– Allows Telnet access by users with Login ID access levels of 1, 2, and 3, with the capability to view system information, change configuration options, and run tests. This is the highest access level allowed.

CAUTION: Before changing the session access level to Level-2 or 3, make sure that the COM port’s Port Access Level is set to Level-1 and that at least one Login ID is set to Level-1. Otherwise, access will be lost. If this occurs, you must reset the unit to the factory defaults and begin the configuration process again. A reset is required if the Communication Port’s Port Use option is set to Net Link (see Table 3-6, General System Options).

Level-2– Allows Telnet access by users with Login ID access levels of 1, 2, and 3, with the capability to view system information and run tests only; they cannot change configuration options.

Level-3– Allows Telnet access by users with Login ID access levels of 1, 2, and 3, with the capability to view system information only; they cannot change configuration options or run tests.

3-90

December 2002

9000-A2-GB31-00

Page 122
Image 122
Paradyne 9820-8M, and 9820-45M, 9820-2M, 9623, 9788 Telnet and FTP Session Options 1, Telnet Session, Telnet Login Required

and 9820-45M, 9123, 9623, 9783, 9720 specifications

The Paradyne 9820-8M, 9788, 9128 standalone, 9128 carrier-mount, and 9820-2M are critical components in telecommunications networks, designed to enhance data transmission and improve connectivity. Each model offers unique features and capabilities that cater to various requirements in both enterprise and service provider environments.

The Paradyne 9820-8M is a multi-service access platform that provides high-speed connectivity for voice, video, and data transmission. It supports multiple protocols, enabling seamless integration into existing infrastructures. Key features include a modular design that allows for scalability and easy upgrades, ensuring that organizations can adapt to evolving demands. Its advanced error correction and QoS (Quality of Service) features ensure reliable performance, even in challenging network conditions.

The Paradyne 9788 serves as a versatile platform for both digital and analog communications. It excels in the delivery of broadband services, supporting T1/E1 lines and providing robust mechanisms for data transmission. This model emphasizes redundancy and resilience, with built-in protection switching capabilities that maintain service continuity during faults or maintenance activities. Its compact design makes it an ideal solution for environments with space constraints.

The 9128 standalone model is aimed at customers requiring an easy-to-deploy solution for point-to-point connections. This model offers critical features such as an intuitive user interface, comprehensive diagnostics, and monitoring capabilities that facilitate system management. It also supports diverse network topologies, making it suitable for various deployment scenarios.

In contrast, the 9128 carrier-mount version is engineered for organizations needing to manage multiple connections within a central office or remote site. This model is specifically designed to be mounted in standard telecom racks, optimizing space utilization while maintaining high performance. Its robust hardware allows for excellent thermal management and environmental resilience.

Lastly, the Paradyne 9820-2M combines versatility with high-performance capabilities, making it a reliable choice for service providers. It features dual-channel support, enabling simultaneous transmission and providing a cost-effective solution for high-capacity data needs. With enhanced security features, including encryption capabilities, the 9820-2M ensures that sensitive information transmitted across networks is protected against unauthorized access.

Collectively, these Paradyne models exemplify advanced telecommunications technology, offering scalability, resilience, and high performance. Their diverse features cater to the unique demands of various users, from enterprise networks to service providers, facilitating the continual evolution of communication technologies.