4. Feature-Specific Configuration
9000-A2-GB31-00 December 2002 4-11
Configuring the DBM Interface to Send SNMP Traps
The ISDN DBM interface can be specified as an interface that monitors and
generates SNMP traps:
Main MenuConfigurationManag ement and Communications
SNMP Traps
The configuration options for doing this include:
nLink Trap Interfaces
nDLCI Traps on Interfaces
nISDN Dial Control Traps
When DBM is selected, trap messages are generated for linkUp and link Down
events on DLCIs and frame relay links for the originating DBM interface onl y. For
peer-to-peer backup, backing up to a neighboring node like a regio nal node, dial
control traps can be sent to trap manager(s).
See Table3-36, SNMP Traps and Trap Dial-Out Opti ons, in Chapter 3,
Configuration Options, for configuration information.
Assigning DLCIs to a Backup Group
DLCIs can be assigned to a Backup Group to reduce backup charges when
redundant PVCs have been configured. This feature prevents backup as lon g as
any DLCI in the group is operational.
nBackup is not initiated as long as one DLCI in the group is operationa l.
nBackup is terminated as soon as one DLCI in the group becomes operatio nal.
See Table3-26, DLCI Record Options, in Chapter 3, Configuration Options, for
configuration information.