3. Configuration Options
9000-A2-GB31-00 December 2002 3-9
8. Select Save, then select PgDn or PgUp. The Class of Service Definitions page
reappears. In the Code Points Assigned column next to your selected name
there is now a Y for Yes.
9. If latency and availability should be measured for the selected name, change
the N in the Measure Latency & Availability column to Y.
10. Select Save.
To configure these options, Service Type on the Easy Install screen must be set to
Frame Relay.
Table 3-3. Class of Service Definitions
Class of Svc Name
Possible Settings: ASCII Text Entry
Default Setting:
For IDs 2–7: blank
For ID 1: Default
Specifies a name to identify a Class of Service definition.
ASCII Text EntryEnter a unique name for the definition (maximum length
8 characters).
Measure Latency & Availability
Possible Settings: N, Y
Default Setting:
For IDs 2–7: N
For ID 1: Y
Determines whether latency and availability are measured for this Class of Service ID.
Display Conditions – This option is set to N and is read-only until the class of service is
defined and code points are assigned to it.
N – Latency and availability are not measured for this Class of Service ID.
Y – Latency and availability are measured for this Class of Service ID.
Code Points Assigned
Possible Settings: Y, N
Default Setting:
For IDs 2–7: N
For ID 1: Y
This read-only field shows whether a Code Point has been assigned to this Class of
Service ID on the Code Point Definitions screen.
N – No Code Point is assigned to this ID.
Y – At least one Code Point is assigned to this ID.