2. Basic Configuration
2-10 December 2002 9000-A2-GB31-00
Network 1 Channel (9720)
Possible Settings: B1, B2
Default Setting: B1
Specifies the B channel used for data transfer when the line rate is 64 kbps.
Display Conditions – Network 1 Channel appears only when Network 1 Operating Rate
is set to 64.
B1 – The B1 channel is used for data transfer.
B2 – The B2 channel is used for data transfer.
Port-1 Port Type (9520, 9788, 9820-2M, 9820-8M)
Possible Settings: E530, V.35, X.21, HSSI
Default Setting:
9520: HSSI
9788, 9820-2M, 9820-8M: V.35
Specifies the port type of the data port.
E530 – The port is configured as an EIA-530-A-compatible DCE. An EIA-530-A-
compatible DTE may be directly connected to the DB25 connector for the port.
V.35 – The port is configured as a V.35-compatible DCE. A V.35-compatible DTE may be
connected to the port using a DB25-to-MS34 adapter.
X.21 – The port is configured as an X.21-compatible DCE. An X.21-compatible DTE may
be connected to the port using a DB25-to-DB15 adapter.
HSSI – The port is configured as a HSSI-compatible DCE. A HSSI-compatible DTE may
be directly connected to the DB25 connector for the port.
Port 1 Port Rate (9520)
Possible Settings (HSSI): 7456, 11184, 17250, 25875, 44736, 51750
Default Setting (HSSI): 51750
Possible Settings (V.35): 512, 1025, 1537, 2050, 2562, 3074, 3587, 4099, 4611, 5124,
5636, 6149, 6661, 7073, 7685, 8197
Default Setting (V.35): 6149
Selects the clock rate in Kbps for the user data port.
Network 1 FRF.8 Encapsulation Mode (9783 and 9788)
Possible Settings: Translational, Transparent
Default Setting: Transparent
Specifies the type of FRF.8 upper-layer protocol encapsulation used on the link for each
pair of interoperable Frame Relay and ATM PVCs.
Translational – Encapsulated data is translated (RFC 1490 to RFC 1483). FrameSaver
multiplexing and SLV communications are not supported in this mode.
Transparent – Encapsulated data is forwarded without being translated.

Table 2-1. Easy Install Configuration Options (7 of 7)