MACH® Series Gas-Fired Boiler

Safety

 

 

Burn hazard! Hot fluids. Use caution when

servicing or draining boiler.

Fire and explosion hazards! Use caution when

servicing burner. Propane (LPG) is heavier than

air and may linger in the combustion chamber,

vent lines, or elsewhere.

Gas leak hazard! Make sure the burner is installed

correctly and burner hood is securely fastened

following any maintenance performed on them.

These connections cannot be tested after the

burner is assembled.

Gas leak hazard! All threaded gas connections

must be made using a pipe compound that is

2.5.3 Crush Hazards

General Warning

Lifting hazards! Use properly rated lifting equipment to lift and position the boiler. The load is unbalanced. Test balance before lifting 3 ft. above the floor. Do not allow personnel beneath the lifted load. Refer to approximate weights in the table below:

resistant to liquefied petroleum. Do not use

Teflontape on threaded gas piping.

Gas leak hazard! Check entire gas train for leaks

after installation. If there is a smell of gas, shut

down the boiler and obtain immediate assistance

from trained service personnel and/or your local

fire department.

Overfire hazard! Possible fire and explosion from

excess gas pressure. Make sure that gas inlet

Boiler Size

300,000 Btu

450,000 Btu

750,000 Btu

900,000 Btu

1,050,000 Btu

Weight in Pounds

354

440

650

700

750

pressure does not exceed 14 inches W.C. to the

regulator.

Overfire hazard! Possible fire and explosion.

Possible malfunction of regulators and/or gas

safety shut off / control valves. Maintain all gas

train components in good condition. Do not alter

wiring connections. Annual inspection by factory-

trained personnel for proper set-up and operation

is recommended.

Overfire and underfire hazards! Possible fire,

explosion, overheating, and component failure.

Do not attempt to adjust firing rate of the boiler.

The firing rate must be adjusted only by factory

trained personnel.

Bump hazard from overhead ductwork and piping. Install components with adequate vertical clearance.

2.5.4 Chemical Hazards

General Warning

Chemical hazards from cleaning products. Use caution when cleaning the system. The use of professional assistance is recommended. Use safe procedures for the disposal of all cleaning solutions.

Combustion Condensate – a pH of approximately

4 to 5 can be expected. Use PVC or CPVC piping. Collection and disposal must be in accordance with all applicable regulations.

Page 3

Page 7
Image 7
Patterson-Kelley MACH-05 manual Crush Hazards, Chemical Hazards, Boiler Size, Weight in Pounds

MACH-05 specifications

The Patterson-Kelley MACH-05 is an innovative high-efficiency boiler designed to meet the demanding needs of today’s commercial and industrial applications. Known for its remarkable performance and advanced technologies, the MACH-05 stands out in the market with its ability to provide reliable heating solutions while minimizing energy consumption and environmental impact.

One of the key features of the MACH-05 is its cascading capability. This allows multiple units to be linked together for enhanced capacity and redundancy. By operating in a modular system, users can achieve optimal energy efficiency by adjusting the number of active units based on real-time demand. This ensures that the system operates at peak efficiency, increasing overall reliability and reducing operational costs.

The MACH-05 is equipped with a fully modulating burner system, which ensures precise control of output and efficiency across a broad range of operating conditions. This advanced burner technology facilitates a significant reduction in fuel usage compared to traditional fixed-output systems. Combined with its high thermal efficiency rating, the MACH-05 is not only environmentally friendly but also economically advantageous for facilities looking to lower energy expenses.

In terms of construction, the MACH-05 features a compact, lightweight design that allows for easy installation and integration into existing systems. Its stainless steel heat exchanger is built to provide superior durability and resistance to corrosion, ensuring a long operational lifespan and reducing maintenance requirements. This design advantage translates into lower lifecycle costs for end-users.

The boiler also incorporates intelligent control systems that enhance operational efficiency. These controls can monitor and adjust parameters in real-time, optimizing performance and offering detailed diagnostics to anticipate maintenance needs. The user-friendly interface makes it easy for operators to manage the system and access vital information regarding performance metrics.

Additionally, the MACH-05 is designed with safety in mind, featuring multiple safety controls and alarms that function to protect both the equipment and personnel. This commitment to safety ensures that facilities can operate with peace of mind, knowing that they have a reliable and secure heating solution.

In summary, the Patterson-Kelley MACH-05 combines advanced engineering, efficiency, and safety features to provide a versatile and dependable heating solution. Its key advantages, including cascading capabilities, fully modulating burner technology, and intelligent controls make it an ideal choice for commercial and industrial applications, paving the way toward sustainable and cost-effective heating systems.