SmartLink 4020 Getting Started Guide

7 • System

 

 

Timeval ::= time in milliseconds

 

Repeatval ::= # of cycles to repeat

 

Tonename ::= "RING_0" "RING_1" "RING_2" "RING_3" "RING_4"

 

"RING_5" "RING_6" "RING_7" "RING_8" "RING_9"

 

Idle ::= "IDLE"

 

Active ::= "ON" "OFF"

 

Inactive ::= Idle "(" Timeval ")"

 

Active ::= Active "(" Timeval ")"

 

Sequence ::= Active Active "," Sequence

 

Repetition ::= "[" Sequence "]" Repeatval

 

Repeat ::= "R"

 

Cycle ::= Sequence Repetition

 

Fullsequence ::= Cycle Cycle "," Fullsequence

 

Cadence ::= Fullsequence Fullsequence "," Repeat Fullsequence

 

"," Inactive "," Repeat

 

Ring ::= Cadence

 

Note The Bellcore standard ring cadence patterns are shown in table 2.

 

Table 2. Bellcore standard ring cadence patterns

 

 

Name

Value

 

 

RING_0

ON(2000), IDLE(4000), R

 

 

RING_1

ON(800), OFF(400), ON(800), IDLE(4000), R

 

 

RING_2

ON(400),OFF(200)]2,ON(800),IDLE(4000),R

 

 

RING_3

ON(300), OFF(200), ON(1000), OFF(200), ON(300), IDLE(4000), R

 

 

RING_4

ON(500)

 

 

RING_5

 

 

 

Supplementary Service Keys

Supplementary Service Keys are key sequences that can enable and disable certain calling features from an analog phone handset attached to the SmartLink 4020.

Note The supplementary service keys must begin with a ‘*’,’#’ character, or f (flash hook) and follow a 1 or 2 numeric digit(s).