Paxar 9445 manual 2-19, Die cut supply requires no sensor adjustment

Models: 9445

1 50
Download 50 pages 20.62 Kb
Page 27
Image 27
Die cut supply requires no sensor adjustment.

2. Loading Supply

Die cut supply requires no sensor adjustment.

1.Do one of the following:

For black mark supply, turn the sensor adjustment knob counterclockwise until it stops. Do not force the knob.

For feed apertures, turn the sensor adjustment knob counterclockwise until it stops. Then turn the knob clockwise as determined below.

Measure from the edge of the supply to the center of the aperture.

Subtract 1/8 inch (3.1 mm) from the measurement.

Multiply the result by 36 (if you are measuring in milli- meters, multiply by 1.41).

For example, if the measurement to the aperture center is 3/8 inch (9.5 mm), turn the knob 9 turns to center the sensor.

Loading Supplies

Sensor

Adjustment

Knob

2.Close the front panel.

2-19

Page 27
Image 27
Paxar 9445 manual 2-19, Die cut supply requires no sensor adjustment