BACK PANEL FEATURES
4 | 5 | 2 |
| 3 |
|
| 6 | 7 | 1 |
INPUT AND COMMUNICATION MODULES
The back panels of IA Series amplifiers provide a location to accept
1.INPUT MODULE
The IA Series comes standard with a basic input module which has plugable input connectors and individual channel rotary attenuators. Your amplifier may have been
2.OUTPUT BARRIER STRIP
A barrier strip is provided for connection of loudspeakers with bare wire or spade lug connec- tors. This barrier strip can accommodate up to two 10 gauge wires per terminal.
3.COMMUNICATIONS BAY
A blank panel comes standard with this amplifier. Your amplifier may have been factory- configured with an optional module. This optional module may be a single communications module or a dual module which includes signal input and processing functions. See the section on Removing or Replacing a Module for more information.
4.IEC POWER CONNECTOR
A standard IEC power connector is located at the upper left corner of the amplifier back
panel. An AC mains cord having an appropriate AC plug for the intended operating voltage is included.
5.CIRCUIT BREAKER
A resettable, protective AC circuit breaker is located towards the upper left of the amplifier’s
back panel. If the breaker has tripped, push it back in to return the amplifier to operating con- dition. If the breaker continues to trip, the amplifier needs servicing. Do not continue to reset the breaker as severe internal damage and safety hazards could occur!
6.SEQUENTIAL TURN-ON CONNECTOR
The IA Series comes standard with remote controllable sequential
6