C1553M-B (4/05) 39
ADD A NEW CANVAS (PELCONET)
Any custom window that is used to display video encoded by a PelcoNet encoder or encoder/decoder must have a PelcoNet MPEG Series canvas
defined for it. Windows used to display analog video that is decoded by a PelcoNet device do not require a PelcoNet MPEG Series canvas.
1. Navigate the Object Browser tree to [project name] > Clients > [client name] > Windows > [window name] > Canvases for the window that
will be used to display video encoded by a PelcoNet encoder or encoder/decoder.
2. Double-click <Add New Canvas>. The Add New Canvas dialog box appears.
Figure 25. Add a PelcoNet Canvas
3. Select PelcoNet MPEG Series from the drop-down box, and then click Settings. The Canvas Settings dialog box appears.
Figure 26. General PelcoNet Canvas Settings
The Selected Compatibilities field lists the types of video signal that the VMX300(-E) video window can display. By default, the window can
display all types of video signal. If you move a signal from the Selected Compatibilities field to the Available Compatibilities field, the
VMX300(-E) video window will not display those types of signals.
A VMX300(-E) video window can display the following types of signals:
MPEG-4: PelcoNet encoders and encoder/decoders support this signal type. For information on configuring PelcoNet 4001A encoder/
decoders for this signal type, refer to Devices. For PelcoNet 3xx encoders, the MPEG-4 signal type corresponds to Stream 1, configured as
described in the Devices section.
MPEG-2: PelcoNet 4001A encoder/decoders support this signal type. Refer to Devices for information on configuring the encoder for
MPEG-2 streaming.
Internal Storage: This is the video signal from a PelcoNet device’s built-in recorder. This signal type applies to any PelcoNet NET350
encoder that has integral recording capability selected. Refer to Devices for instructions on configuring integral recording capability.
MPEG-4 Secondary: PelcoNet 3xx encoders support this signal type. The MPEG-4 Secondary signal type corresponds to Stream 2,
configured as described in the Devices section.
NVR300: The video signal from an NVR300. This signal type applies to PelcoNet encoders and encoder/decoders that have been configured
to have their streams recorded by an NVR300. Refer to Devices for more information.