C1553M-B (4/05) 87
CONFIGURE THE GENERAL TAB
Figure 98. General Tab for KBD300
Use the General tab to enter a location name and an optional description. The location name is used to identify the device. The location name
can be a maximum of 50 characters and can include any letter, digit, or special character, with the exception of single and double quotation
marks. Location names are not case sensitive.
CONFIGURE THE COMMUNICATIONS TAB
1. Connection Type: Specify the type of connection between the keyboard and the switcher.
DIRECT SERIAL: The keyboard is connected directly to the VMX300(-E) workstation using a PV140 converter.
INTERNET PROTOCOL: The keyboard is connected to the serial port on a networked device, such as a PelcoNet device.
MODEM: This feature is reserved for future development.
2. Settings: Complete the instructions provided below for the appropriate connection type specified in Step 1.
Direct Serial Settings
Figure 99. Communications Tab for KBD300 Serial Settings
a. Select the COM port that the keyboard is connected to from the drop-down box.
b. The remaining settings should specify 9600 baud, odd parity, 8 data bits, 1 stop bit, and no flow control.
c. Refer to Step 3 for instructions on completing the fields in the Miscellaneous section.