Connecting a Relay Device

The camera has an output for activating an external device. It supports both momentary and continuous relay operation.

You can operate the relay interactively during an active connection, or it can operate automatically to coincide with certain events. Typical applications include turning on lights or other electrical devices or activating a door, gate, or lock.

WARNING: Do not exceed the maximum rating of 12 VDC, 0.15 A.

Figure 9 shows how to wire the relay with its power source to the camera.

A1

R1

12 VDC, 150 mA MAX

24V~

Figure 9. Relay Wiring

Connecting Alarms

The camera provides an alarm input for external signaling devices, such as door contacts or motion detectors. Both normally open and normally closed devices are supported.

Supervised Alarms

When an alarm is configured as a supervised alarm, the camera maintains a constant electrical current through the alarm circuit

(3.3 VDC, 1 ohm). If the alarm circuit length changes, due to an electrical short or a bypass, the voltage fluctuates from its normal state and activates an alarm.

NOTE: Install the 1-kohm resistor as close to the switch as possible.

Figure 10 illustrates the alarm and no alarm conditions of a supervised alarm input. Whether the alarm is normally closed or normally open, neither a cut nor a bypass can defeat these alarms.

 

NORMALLY CLOSED

 

 

NORMALLY OPEN

NO ALARM

1 KΩ

 

NO ALARM

1 KΩ

GND

 

+V

GND

 

ALARM

1 KΩ

 

ALARM

1 KΩ

GND

 

+V

GND

 

ALARM

1 KΩ

 

ALARM

1 KΩ

GND

 

+V

GND

 

 

CUT

 

 

CUT

ALARM

1 KΩ

 

ALARM

1 KΩ

GND

 

+V

GND

 

 

BYPASS

 

 

 

 

 

 

 

BYPASS

Figure 10. Supervised Alarm Conditions

Figure 11 illustrates the wiring configuration for supervised alarm inputs.

 

 

 

 

NORMALLY CLOSED

 

 

 

 

NORMALLY OPEN

 

 

 

 

 

 

 

 

 

 

 

 

 

A1

 

A1

 

 

 

 

 

1 KΩ

 

 

 

 

 

 

1 KΩ

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+V

+V

+V

+V

Figure 11. Supervised Alarm Input Wiring

C2953M-A (5/09)

15