Spin Fryer I12 Cooking Computer

Pitco P/N 60149505

4To Enter Programming Level 3 (for the Technician)

With no cook timers running, displays will show one of the following displays:

;

, or

.

Press the key. The left display will show . The right display will be blank.

Enter password entry.

Level 3 Password

 

6

6

8

5

using the product keys as a numeric keypad for

Display will show

. Product key indicators will

illuminate to prompt operator to select a key. This section details parameters that may be changed in Level 3 programming.

4.1Offset the Temperature Display:

This adjustment allows the displayed temperature value to be offset to reflect the true center vat temperature while reading the probe tip temperature. Default value is +2. With zero value set, displayed values are the probe temperature.

With display showing

press product key 1.

Display shows [OFF nn F] [DEGREES], where “nn” is the value of the adjustment.

Negative values are preceded with a minus sign. To change this value, use the product keys for numeric entry of a new value.

1

Press the key. Display will show [POSITIVE] [DEGREES]. Use the product key to scroll choices (Positive or Negative value).

After selection, press the

key. Display shows

.

Note: Computer Display Temp Center Vat Temp = Offset (+/-). Example: Computer Display shows 350F while Center Vat Temp measures 352F. 350F – 352F = - 2 °F. A negative offset value. Proper equipment and expertise is required to correctly adjust this value. Even small changes may negatively affect cooking performance.

4.2Melt Cycle ON Time

With display showing

press product key 2.

Display shows [MLTON :nn] [MELT ON], where “nn” is the value, in seconds, of time for a melt cycle heat pulse.

To change this value, use the product keys for numeric entry of a new value.

Press the

key. Display returns to

.

2

Page 13 of 28

L22-355 Rev 1

Page 13
Image 13