Spin Fryer I12 Cooking Computer

Pitco P/N 60149505

4.3Minimum ON and OFF Cycle Time

With display showing

press product key 3.

Display shows [MIN ON:nn] [MIN ON], where “nn” is the value, in seconds, of time for minimum heat pulse period.

To change this value, use the product keys for numeric entry of a new value, then

press the key to save.

Display shows [MIN OFF:nn] [MIN OFF], where “nn” is the value, in seconds, of time for minimum heat off period. Use the product keys for numeric entry of a new value.

Press the

key. Display now shows

.

4.4Recovery Times:

This controller maintains a record of heat up times for the appliance. A poorly running appliance will have increased recovery times stored in this display. There is no selection done here, just the display of recovery time values.

With display showing , press the product key [0].

Display will show

.

Press product key 6; display will show [RECOVERY] [TEST].

Press the product key [0]. Display will show [FnnnLyyy], where nnn is the factory recovery value, and yyy is the last warm- up recovery value.

After recording these values, press the key. Display will again return to

.

3

4

L22-355 Rev 1

Page 14 of 28

Page 14
Image 14
Pitco Frialator L22-355 service manual Minimum on and OFF Cycle Time, Recovery Times