Spin Fryer I12 Cooking Computer

Pitco P/N 60149505

4.8.2Heat Demand Profile

With display showing

, press product key 3. Display will show

[xxxxxxx] [HEAT DEM], where xxxxxxx may be one of 6 heat control profiles listed below.

1.[GENERIC 1] for gas fired fryer appliance. This is the factory default.

2.[GENERIC 2] for electric fryer appliances, and model SGH50.

3.[TEST] for use in special cook testing, do not select this setting for normal operations.

Use product key [0] change value, then press the to save choice Display returns to

.

4.8.3Shake Alarm Duration

With display showing

, press product key 4. Display will show

[SH-DUR:nn] [DURATION], where “nn” is the time in seconds the shake alarm will sound. Use

product keys for numeric entry of desired value, then press the

to save choice. Display

returns to

.

 

3

4

4.8.4Hold Alarm Duration

With the display showing

, press product key 5. Display will

show [HD-DUR:nn] [DURATION], where “nn” is the time in seconds the hold alarm will sound.

Use product keys for numeric entry of desired value, then press the to save choice.

Display returns to

.

4.8.5Cancel Duration

With the display showing

, press product key 6. Display will

show [CANCEL:nn] [DELAY] , where “nn” is the time in seconds the operators must press a product key to cancel a cook. Use product keys for numeric entry of desired value, then press

the

to save choice. Display returns to

. Default value is

2 seconds.

 

5

6

4.8.6Configuration Value

With display showing

, press product key 7. Display will show

[CFG hhhh], where “hhhh” is a hexadecimal checksum of the configuration memory contained in the controller. Modifications to any part of the setup of this control will change the check

sum value. Press the

display will return to

.

7

Page 17 of 28

L22-355 Rev 1

Page 17
Image 17
Pitco Frialator L22-355 service manual Heat Demand Profile, Shake Alarm Duration, Hold Alarm Duration, Cancel Duration