Pitco Frialator L22-355 service manual Other Displays

Models: L22-355

1 28
Download 28 pages 37.69 Kb
Page 23
Image 23
6Other Displays:

Spin Fryer I12 Cooking Computer

Pitco P/N 60149505

6Other Displays:

Open probe detection is standard on all Pitco controls. If probe is detected open, normal heating and cooking activities are suspended.

This display warns operators that the vat temperature has exceeded set temperature by +40°F (+22°C), or an absolute maximum of 410°F (210°C). The alarm will also sound. This display does not show the status of the mechanical high limit switch.

This message indicates that the drain valve has been opened, the vat is assumed to be empty by the controller. Normal heat control activities are suspended. Display will show an alternating message [DRAINING] / [TURN OFF]. To restore to normal operation, close the drain value. Display will show [TURN OFF].

Turn controller off, and refill the vat. Continue with normal operations at section 1.

This message indicates that the heating system failed to respond. Typically, the high temperature limit switch has tripped and is in need of resetting. In the case on gas fired appliances, this message will display if the pilot fails to light or is detected marginal by the ignition module. Display will show an alternating message [HEAT] / [FAILURE].

This message indicates a shorted probe. If probe is detected as a short circuit, normal heating and cooking activities are suspended. Display will show an alternating message

[SYSTEM] / [FAILURE].

This message indicates that a recoverable system error has occurred. Press ‘6’ for YES to perform a factory reset or ‘0’ for NO to return to OFF. Normal use of the system will only resume when a factory reset has been performed. Display will show an alternating message [FACTORY] / [RESET].

Page 23 of 28

L22-355 Rev 1

Page 23
Image 23
Pitco Frialator L22-355 service manual Other Displays