INSTALLATION & OPERATIONAL SELV MANUAL

4.14 Password Change or Required?

With factory settings, an operator password is not required to enter programming Levels 1 and 2. The password may be activated or changed in this section.

With display showing [PROGRAM], press the product key [0]. Display will show

 

2

 

[SELECT] [OPTIONS].

 

 

 

 

 

 

Press product key 2, display shows [SET PASS] [NEW PASS]. Use the product key [0]

 

 

 

to scroll through choices [NO PASS] or [PASS REQ]. Press [P] key to save choice.

 

 

 

 

 

 

 

 

 

 

 

If [NO PASS] is selected Display returns to [PROGRAM].

 

 

If [PASS REQ]. is selected, display will show [PASSnnnn] [NEW PASS] to prompt for new

 

 

password. Displayed value “nnnn” is the current password. Use the product keys for numeric entry to change password. Press [P] key to save choice. Display shows [PROGRAM].

Note: The factory default password (6684) will always work even if a different password is selected above.

4.15 Beeper Volume and Tone:

Volume and Tone of the beeper alarm may be changed in this section. Volume ranges are 1,2 and 3, where 3 is the loudest setting.

With display showing [PROGRAM], press the product key [0].

 

 

3

 

Display will show [SELECT] [OPTIONS]. Press product key 3, display shows

 

 

[VOLUME n] [BEEPER]. Use the product key [0] to scroll through choices (n= 1,2,3, or

 

 

T). Beeper volume will change as each selection is made.

 

 

If “T” is selected an additional display is shown, [TONE n] [BEEPER]. Use the product

 

 

 

 

 

 

key [0] to scroll through choices (n= 1,2,3). Beeper tone will change as each selection is made. Press [P] key to save choice. Display shows [PROGRAM].

4.16 Language Selection:

With display showing [PROGRAM], press the product key [0]. Display shows [SELECT] [OPTIONS].

Press product key 4, display shows [ENGLISH] [LANGUAGE].

Use the product key [0] to scroll through choices (ENGLISH, ESPANOL, FRANCAIS, DEUTSCH, HOLLAND).

Press [P] key to save choice. Display shows [PROGRAM].

4

4.17 Melt Cycle Type:

This adjustment allows selection of the melt cycle type, or, disabling the melt cycle requirement when starting the appliance from a cold start.

With display showing [PROGRAM], press the product key [0].

 

Display will show [SELECT] [OPTIONS].

 

5

Press product key 5, display shows [LIQUID], the default setting.

 

Use the product key [0] to scroll through choices (liquid, solid, no melt).

 

Press [P] key to save choice. Display will again return to [PROGRAM].

 

 

 

4.18 Recovery Test Value:

This controller maintains a record of heat up times for the appliance. A poorly running appliance will have increased recovery times stored in this display. There is no selection done here, just the display of recovery time values.

With display showing [PROGRAM], press the product key [0]. Display shows [SELECT] [OPTIONS].

Press product key 6; display will show [RECOVERY] [TEST].

Press the product key [0]. Display will show [FnnnLyyy], where nnn is the factory recovery value, and yyy is the last warm up recovery value. After recording these values, press the [P] key. Display returns to [PROGRAM].

6