Pitco Frialator SELV14T operation manual Troubleshooting Power Failure, High Temperature Limit

Models: SELV14 SELV14T

1 36
Download 36 pages 23.84 Kb
Page 31
Image 31

SELV INSTALLATION & OPERATIONAL MANAUAL

13 TROUBLESHOOTING

13.1 POWER FAILURE

If electric power is removed for any reason, the appliance will shut down.

To restart the appliance, follow the appliance start up procedure in (See section 3.3.)

CAUTION

DO NOT attempt to operate this appliance during a power outage.

13.2 HIGH TEMPERATURE LIMIT

This appliance is equipped with a high temperature limit switch. The high temperature limit switch will stop the appliance from heating if the internal cook tank reaches an unsafe temperature. In the event that the high temperature limit has tripped, Please refer to the following procedure to reset the switch.

a.Turn the appliance off.

b.Allow the appliance time to cool to room temperature.

c.Add oil to the cook tank as needed.

d.Remove the access screw located under the basket support. Picture 1.

e.Use a small diameter tool ( 1/8” maximum) such as a small Philips screwdriver to press the reset button. Picture 2.

f.Install the Access cover screw.

g.The high limit switch is now reset and the appliance is ready for start up.

h.If the reset becomes tripped again, discontinue using the fryer, and call for service.

Picture 1

Use a flat screw driver to remove the screw marked “Reset Button”(Full pot shown). SELV14T reset buttons are under the outer Screws.

Picture 2

Use a small diameter rod (1/8” max.), or a Philips screwdriver to reach through the access hole and press the reset button.

WARNING

DO NOT add oil to the frryer until it has been given ample time to cool down. Failure to do so may result in damage to the appliance and/or injury to the operator.

13.3 DRAIN VALVE INTERLOCK

Your appliance is equipped with a drain valve interlock circuit to prevent the appliance from heating if the frypot drain valve is opened. Refer to the following procedure to resume operation after the drain valve interlock is tripped.

1.Turn the appliance OFF.

2.Close the tank drain valve and fill the tank with oil/shortening.

3.Turn the appliance ON.

31

L20-406 Rev 5 (3/14)

Page 31
Image 31
Pitco Frialator SELV14T operation manual Troubleshooting Power Failure, High Temperature Limit, Drain Valve Interlock