INSTALLATION & OPERATIONAL SELV MANUAL

4.10.3Hold Time

Cooked product may stand in holding bins for a period of time. This timer produces an alarm to

inform operators to discard old product and start a new cook. Default for this

value is zero, meaning the Hold Time is inactive. Display is showing [nHD mm:ss] [TIME], where “n” is the key number, “HD means HOLD, and “mm:ss” is minutes and seconds.

Use the product keys for numeric entry to adjust the current setting. Press the [Clock] key to save hold time and continue setup for this product key.

4.10.4Hold Pre-Alarm

Hold Pre-Alarm is a timer setting that is used to warn operators that the Hold Time is about to expire. To use Hold Pre-Alarm, time value must be a non-zero value, and must be set to a value less than Hold Time. Default value is zero, meaning the Hold Pre-Alarm is inactive.

Display is showing [nPA mm:ss] [TIME] where “n” is the key number, PA means Pre-Alarm, and “mm:ss” is minutes and seconds.

Use the product keys for numeric entry to adjust the current setting.

Press the [Clock] key to save cook time and continue setup for this product key. Note: Value entered for Hold pre-alarm time is the hold time minus the pre-alarm time. Example: 15:00 hold time with a 5:00 prealarm time, the value you enter would be 10:00 minutes.

Display will again return to [SELECT] [TIME]. Repeat steps from 1 to make changes to any other product keys or continue.

4.11 To Exit Level 1 programming:

Display shows [SELECT] [TIME]. Continue to make changes or exit here in next step. Press the [P] key. Display shows [PROGRAM]. To exit Level 1 programming, press the [P] key again. Displays will show [HEATING], [MELT] [LIQUID (or SOLID)], or [READY].

4.12 To Enter Programming Level 2 (for the Store Manager)

The display must show [PROGRAM] from (See section 4.8 “To Enter Programming

 

0

Level 1” (For the Store Manager). to change these options. When the product key [0]

 

is pressed, the display will show [SELECT] [OPTIONS]. Indicator lights above

 

product keys will illuminate to represent options that may be changed. Each option

 

listed below uses the product key [0] to toggle or scroll through available choices in

 

 

the display. When the correct value is displayed, press the [P] key to save choice. The display will again return

to [PROGRAM] for another option selection.

4.13 Fahrenheit or Celsius Display:

The Controller will display temperatures in the Fahrenheit or Celsius scales. The default scale is °F. With display showing [PROGRAM], press the product key [0].

Display shows [SELECT] [OPTIONS].

Press product key 1, display shows [DEGREE n] [F OR C], where “n” is the current setting.

Use the product key [0] to scroll through choices (F or C). Press [P] key to save choice. Display shows [PROGRAM].

1

19

L20-406 Rev 5 (3/14)

Page 19
Image 19
Pitco Frialator SELV14T To Exit Level 1 programming, To Enter Programming Level 2 for the Store Manager, Hold Time