Pitco Frialator SELV14T operation manual Troubleshooting Charts, Fryer Troubleshooting Chart

Models: SELV14 SELV14T

1 36
Download 36 pages 23.84 Kb
Page 32
Image 32

SELV INSTALLATION & OPERATIONAL MANAUAL

14 TROUBLESHOOTING CHARTS

14.1FRYER TROUBLESHOOTING CHART

Problem

Probable Causes

Corrective Actions

 

No power to appliance.

Check main building power supply.

 

Circuit Breaker tripped.

Reset circuit breaker.

Computer Controller

Power Cord loose or not

Connect power cord. Check power cord where it

enters the rear of the fryer's entrance box. Verify

display doesn't light.

connected.

that it os plugged all the way into the receptacle.

 

 

 

 

 

Fuse blown.

Contact Authorized Service Company.

 

Transformer Defective.

Contact Authorized Service Company.

 

Defective Controller.

Contact Authorized Service Company.

Controller is on and

Computer is in Melt Cycle

Allow time for unit to heat up.

appliance will not

High temperature limit has

Allow appliance to cool and reset High

heat up.

tripped.

temperature limit.

 

 

 

Appliance will not

Faulty temperature probe.

Contact Authorized Service Company.

maintain temperature

Faulty High temperature limit.

Contact Authorized Service Company.

properly.

 

 

 

Computer display

 

 

shows off and can not

Faulty computer

Contact Authorized Service Company.

be turned on.

 

 

Oil Temperature is

Temperature Calibration

Refer to section 3.8

hotter, or cooler than

shown by Computer

Defective Temperature Probe

Contact Authorized Service Company.

Controller

 

 

Computer Controller

Blue drain vavle is not

Close blue drain valve handle.

completely closed.

displays "DRAINING"

 

 

Improperly adjusted or

 

or "TURN OFF"

Contact Authorized Service Company.

defective drain switch.

 

 

Computer Controller

 

 

displays "PROBE

Open temperature probe

Contact Authorized Service Company.

OP" "OPEN"

 

 

32

L20-406 Rev 5 (3/14)

Page 32
Image 32
Pitco Frialator SELV14T operation manual Troubleshooting Charts, Fryer Troubleshooting Chart