Pitco Frialator SELV14 Temperature Check, ANNUAL/PERIODIC Preventative Maintenance and Inspection

Models: SELV14 SELV14T

1 36
Download 36 pages 23.84 Kb
Page 29
Image 29

INSTALLATION & OPERATIONAL SELV MANUAL

11.2 TEMPERATURE CHECK

Use a high grade pyrometer or digital thermometer suitable for temperature up to 380°F (182°C). Place the thermometer in the oil above the tip of the fryer’s temperature probe with in 1” (2.54 cm) 25.4 mm). Be sure not to touch the heat tube since this will measure incorrect temperatures.

Check that the controllers set point and thermometer is within +/- 5°F (2.8°C). If your measurement are off, re-measure again before contacting an Authorized Service Company for further assistance.

12 ANNUAL/PERIODIC PREVENTATIVE MAINTENANCE AND INSPECTION

This section should ONLY be performed by a qualified service technician as part of a regular kitchen maintenance program. This inspection should take place a minimum of once a year by an Authorized Service Technician recommended by Pitco. It may be necessary perform this inspection more than once a year.

12.1.1SAFETY EVALUATION

Check power cord and plug.

Check all exposed wiring connections, switches, and indicator lights.

Check legs, casters, wheels, plate welds and ensure all nuts and bolts are secured.

12.1.2MECHANICAL INSPECTION

Check fry tank for shortening leaks and excessive oil build up

Check for oil migration (Clean as required)

Check hood drain cup, ensure that it is not dripping onto the appliance. Empty as necessary.

Check hood baffle for clean surface, oil/water condense can drip onto appliance.

Check drain/filtration system (if equipped) for leaks

Check for missing fryer parts.

Check for missing fasteners

12.1.3TEMPERATURE CONTROL SYSTEM

Check electrical connections and harnesses

Check temperature probes and limits for carbon build up and plating. Clean as required

Check proper mounting of probes and sensors and verify all fasteners are secure.

Check DVI Drain Valve Interlock drops out controller.

Check Controller/thermostat features to ensure they are functioning.

Check Temperature Calibration

12.1.4FILTER SYSTEM (IF EQUIPPED)

Check electrical connections and harnesses.

Check IEC power cords are fully engaged and secure.

Check for any air or shortening leaks and for excessive oil build-up.

Check O-Ring on filter pickup tube and replace as needed.

Check filter strainer on pickup tube.

Check operation of drain valve and DVI drain valve interlock.

Check operation of return oil valve and its pump switch.

Check all hardware in filter pan.

Check filter operation by filtering the fryers.

Check pump motor amp draw compare to nameplate amperage.

Check pump and motor; clean any excess oil from pump assembly.

Check all filter hoses for leaks and integrity.

29

L20-406 Rev 5 (3/14)

Page 29
Image 29
Pitco Frialator SELV14T operation manual Temperature Check, ANNUAL/PERIODIC Preventative Maintenance and Inspection