Operation

PIP Position: To change the position of the PIP image, choose PIP Position from the System menu; see Figure 4-13.Choose one of the following:

Top Left: This places the PIP source into a 644x362 designated image area at the top left of the screen.

Top Right: This places the PIP source into a 644x362 designated image area at the top right of the screen.

Bottom Left: This places the PIP source into a 644x362 designated image area at the bottom left of the screen-safe area of the DMD.

Bottom Right: This places the PIP source into a 644x362 designated image area at the bottom right of the screen-safe area of the DMD.

Picture-By-Picture:This reduces the designated image area of the Active source to 921x518 and places it next to the PIP source, which is also in a 921x518 image area. These two images are centered on the screen.

Split Screen: This is a special mode in which the active source is also used as the PIP source and placed in a PIP area equal to half the display on the left side. This results in the right half of the image being the active source and the left half is the PIP source. The PD8130/PD8150 applies the User Memory 2 settings to the PIP image.

Split-screen mode is useful for viewing “before” and “after” settings for Sharpness, Noise Reduction and other advanced image parameters. See Figure 4-14.

DMD Area 1920x1080

644x362

 

 

PIP

 

(top right)

921x518

921x518

PBP1

PBP2

 

 

Screen-Safe Area 1842x1036

Figure 4-13. PIP and PBP areas for 1080p Display

Planar PD8130/PD8150 Installation/Operation Manual

55