Table 5-1. Troubleshooting Chart (continued)

Symptom

Possible Cause(s)

Solution

Image appears “washed out” and/or dark areas appear too bright.

• Brightness is set too

• Lower the brightness

high.

setting.

Colors in the image are

• The Red/Pr, Green/Y or

• Ensure that the source

swapped; for example,

Blue/Pb outputs from

outputs are connected

reds appear blue or vice

the source are

to the correct

versa.

connected to the

PD8130/PD8150 input.

 

wrong inputs on the

 

 

PD8130/PD8150.

 

 

 

 

LED is flashing alternating

• The lamp cover is open.

green and red.

The lamp has failed or

 

 

exceeded its usage life.

LED is flashing red.

PD8130/PD8150 internal

 

 

temperature is too high.

Close the lamp cover.

Replace the lamp with a new one.

Power off the PD8130/PD8150 and allow it to cool down. Ensure that the intake and exhaust vents are not blocked. Turn the projector back on. If the problem persists, please contact Planar Technical Support for assistance.

LED lights solid red.

• Fans are not working

• Please contact Planar

 

properly or power-on

Technical Support for

 

self-test has failed.

assistance.